In the case of Img.2, if the parameter No.1817#3 is set to 1 and No.1868 (threshold
position) is set to 290.0, the scale data of the threshold position or more is converted to
the data which is subtracted by the amount of one rotation (360000 in this case), as
shown in Img.3. Therefore, the scale data is continuous as -85000 ~ 5000 in movable
range and the machine position of NC can become correct value as -45.000 ~ 45.000.
The parameter No.1868 (the threshold position) is required to be set the position out of
movable range and positive value. (0.0∼360.0: Set to 290.0 instead of –70.0, in this
case.)