FANUC Series 15i/16i/18i/21i
Remote Diagnostic Function
Host Software (for Windows)
-63555EN
Drawing No.
Title
Page
3 1999.7.05 Y.Wakinotani 15i is added T.Ohtsuki
2 1999.3.09 N.Hatanaka Overall revision T.Kurokawa
Set No.0002#0(RDG) to 1 when starting the remote diagnosis and to 0 when ending it.
During No.0002#0 = 1, the status of the telephone line can be checked as follows.
Function key [MESSAGE] -> the next key < “>” > -> Soft-key <RMTDGN>.
In the case that CNC is working properly in data waiting status, the following
message appears.
In the case that CNC has some problem, the following message appears.
If this happens, turn the parameter No.0002#0 to “0” once and “1” again.
In the case that the same error message still appears, check the serial
cable connection after powering OFF the CNC and PC.
(Note)The reader/puncher interface option is required.
15i
The following parameter setting is required.
- No.0000#2(ISP) = 1
- No.0000#3(NCR) = 1
- No.0000#4(EIA) = 0
- No.0020-0023 = 12
- No.0040 = 1-3
Set No.5001-5003, 5110-5162 in accordance with No.0040
Reader/punch device specification number must be set to 3
Set No.0000#6(RDN) to 1 at starting the remote diagnosis and to set 0 at ending it.
The CNC initialize the serial port using the above parameters when the parameter
No.0000#6 is set to 1.
(Note)The reader/puncher interface option is required.
LINE STATUS : DATA
LINE STATUS : LINE ERROR