FANUC MANUAL GUIDE i, Specification Additional Manual Page 9

Additional Manual
Ed.
Date
Design Description
Name
Draw.
FANUC MANUAL GUIDE i
SPECIFICATION
A-90155
Page
FANUC LTD.
9/3
2005.7.21
Correction of part2005.8.12
15inch screen mode
MDI key operation
<> move display of data-table to left
<> move display of data-table to right
<> move display of data-table to upward
<> move display of data-table to downward
PAGE UP invalid
PAGE DOWN invalid

Contents Summary of FANUC MANUAL GUIDE i, Specification Additional Manual

  • Page 1. FANUC MANUAL GUIDE i Tool attachment/detachment management function Specifications FANUC MANUAL GUIDE i Name SPECIFICATION 2005.8.12 Correction of part 2005.7.21 Draw. A-90155 Page Ed. Date Design Description FANUC LTD. 1/3
  • Page 21 OUTLINE This function can execute the following contents with the cartridge number and the pot number specified at magazine management table screen - It is possible to register automatically tool management data an d delete tool management data. - It is possible to manage tool attachment history d
  • Page 32 DETAILS 2.1 Tool attachment function Tool attachment functon can attach a tool to an empty pot which are specified at magazine management table screen by inputing tool management data at tool attachment screen. Tool attachment data is registered for the following data. - Register tool attachment d
  • Page 4soft-key EXEC CANCEL 15inch screen mode FANUC MANUAL GUIDE i Name SPECIFICATION 2005.8.12 Correction of part 2005.7.21 Draw. A-90155 Page Ed. Date Design Description FANUC LTD. 4/3
  • Page 5MDI key operation number key input value PAGE UP go back to previous page PAGE DOWN go to next page <↑> move cursor to upward <↓> move cursor to downward <←> move cursor to left <→> move cursor to right soft key operation [EXEC] - Tool attachment and data registration that is inputted to Magazine ma
  • Page 62.2 Tool detachment In Magazine management table screen set magazine number and pot number, and input the cause of tool detachment , so you can detach tools. If tool detachment is executed normally, it is performed as follows. - tool data that belongs to the magazine number and pot number inputed in
  • Page 7soft-key operation [CAUSE1] - [CAUSE5] - after pressing [DETACH] soft-key, to select the result of tool detachment you have to select and press one soft-key: After the soft-key is pushed, the tool will be detached. In automatic tool detachment mode, “POT NO.*** TOOL OUT” is displayed in the message
  • Page 82.3 Tool attachment / detachment history Tool attachment/detachment history can be displayed by selecting tab for them. The position of tabs can be changed by parameter setting. 2.3.1 Tool attachment history In tool attachment screen tool attachment data , magazine number, pot number and date is sav
  • Page 915inch screen mode MDI key operation <←> move display of data-table to left <→> move display of data-table to right <↑> move display of data-table to upward <↓> move display of data-table to downward PAGE UP invalid PAGE DOWN invalid FANUC MANUAL GUIDE i Name SPECIFICATION 2005.8.12 Correction of pa
  • Page 10soft key operation [CHCURS] - change cursor mode: [←PAGE] - go back to the previous history of tool attachment : [PAGE→] - go to the next history of tool attachment : [OUTPUT] - output the history data of tool attachment to a memory-card : [INPUT] - input the cause data of tool detachment from a mem
  • Page 112.3.2 Tool detachment history To press [DETACH] softkey, tool management data , magazine number, pot number, date and cause is saved. This history function manages till 10 histories, if over 10, the eldest history data is deleted. The following screen is displayed to select “TOOL DTA HIS” tab. the f
  • Page 1215inch screen mode soft key operation [CHCURS] - change cursor mode: [←PAGE] - go back to the previous history of tool attachment : [PAGE→] - go to the next history of tool attachment : [OUTPUT] - output the history data of tool attachment to a memory-card : [INPUT] - input the cause data of tool de
  • Page 132.4 lay-out of displayed items The displayed items customizing in tool management expanded function changes lay-out of tool attachment screen’s and tool detachment history screen’s displayed items. In following point it differs from the tool management screen. 1. Date is displayed in regular space i
  • Page 142.5 memory –card input/output It is available to input/output the cause data of tool detachment as a text file in tool detachment history screen. Only file output is available about tool attachment history and tool detachment history data. output data input/output file name the cause of tool detachm
  • Page 152.5.2 Tool detachment cause data input The following soft-key is displayed in the attachment or detachment history screen. CURSOR <-PAGE PAGE-> CLOSE After [<] or [>] is pushed, the following soft-key is displayed. OUTPUT INPUT Push [INPUT] and the following softkey is displayed. CAUSE CANCEL Push [
  • Page 163 Parameters 14845 TOLTAB The order of "TLMNG DATA", "MAGAZINE", "OFFSET", and "TOOL DATA" tabs in the “TOOL MANAGEMENT DATA” window can be changed by setting this parameter. Please set the order which you wants to display as follows. the 1st place of decimals : TLMNG DATA the 2nd place of decimals
  • Page 17The order of displaying default is as follows. The 5th : TLGEOM DATA The 6th : TL_ATA_HIS The 7th : TL_DTA_HIS If big tool function and tool attachment detachment function are used and you want to change the order of tab, please set 1 - 7 to each place of decimal in paramter 14845 and 14846. FANUC M
  • Page 184 warnings and messages Message Contents NOT EMPTY POT The pot number specified to attach a tool is not empty.Please specify an empty pot number. NOT EMPTY There is no empty tool management TOOL_NO number to be add to tool management data at tool attachment screen.Please check tool management data t