A-79361E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
9/9
page
FANUC Series 30i-MODEL A
Start lock, Interlock signal
for each axis and direction
#7 #6 #5 #4 #3 #2 #1 #0
5009 GSC
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be turned off before
operation is continued.
# 0 GSC Specifies from which the offset write signal is to be input for the direct
input of tool offset value measurement B function, as follows:
0: To be input form the machine.
1: To be input from the PMC.
NOTE
If interlock for each axis and direction is enabled (bit
3 or parameter No. 3003 (DIT) is 0), its input is also
switched from the machine to the PMC.
Note
NOTE
1. The interlock signal for each axis and direction (T series) is supported
regardless of whether the direct input of tool offset value measurement B
is provided.
2. The “I” is indicated at the axis status that is displayed to the left of axis
name in the coordinate display screen.