Series 30i-MODEL A, Start lock, Interlock signal for each axis and direction Additional Manual Page 2

Additional Manual
FANUC Series30i –A newly additional functions
Drawing number Functions
1 A-79227E
External Data Input
2 A-79226E One Touch Macro call
3 A-79196E
Temporary absolute coordinate setting
4 A-79354E
System alarm
5 A-79349E Touch Panel Control
6 A-79253E
Distance coded linear scale interface
7 A-79364E
Linear scale with distance-coded reference marks (serial)
8 A-79343E Input of tool offset Value Measured
9 A-79344E Input of tool offset Value Measured B
10 A-79345E Tool Management Extension Function
11 A-79346E Tool Management Function Oversize tools Support
12 A-79342E
External touch panel interface
13 A-79348E Tool center point control for 5-axis machining
14 A-79381E Tool axis direction tool length compensation
15 A-79355E
Index Table Indexing Function
16 A-79356E
Rotary axis control function
17 A-79357E
Extended External Machine Zero Point Shift function
18 A-79340E
Diameter and Radius setting switching function
19 A-79341E
Active offset value change function based on manual feed
20 A-79358E
Single Direction Positioning function
21 A-79366E
Background Editing
22 A-79368E
Memory Card Program Operation/Editing
23 A-75359E
Rotary table dynamic fixture offset
24 A-79351E
Three-Dimensional Error Compensation
25 A-79260E
Power Mate CNC Manager
26 A-79350E
Real-time Custom Macro
27 A-79360E
Improvement of stored stroke limit 1
28 A-79361E
Start lock, Interlock signal for each axis and direction
29 A-79367E
Rapid traverse override 0.1%
30 A-79363E
In-position check and servo error excess check in Torque limit
31 A-79414E
Small-Hole Peck Drilling Cycle
32 A-79352E
I/O Link β Manual handle interface
(Peripheral equipment control interface)

Contents Summary of Series 30i-MODEL A, Start lock, Interlock signal for each axis and direction Additional Manual

  • Page 1TECHNICAL REPORT NO. TMN 04/020E Date :Mar .30, 2004 General Manager of Software Laboratory FANUC Series 30i-A Newly additional functions 1. Communicate this report to: Your information only GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agency End user 2. Summary for Sale
  • Page 2FANUC Series30i –A newly additional functions Drawing number Functions 1 A-79227E External Data Input 2 A-79226E One Touch Macro call 3 A-79196E Temporary absolute coordinate setting 4 A-79354E System alarm 5 A-79349E Touch Panel Control 6 A-79253E Distance coded linear scale interface 7 A-79364E Li
  • Page 3FANUC Series 30i-MODEL A Start lock, Interlock signal for each axis and direction Specifications FANUC Series 30i-MODEL A Title Start lock, Interlock signal for each axis and direction Draw A-79361E No. Ed. Date Design Description page 1/9 Date Jan.06.’04 Design. Apprv.
  • Page 4The following descriptions have been added in the “2.5 START LOCK/INTERLOCK” in the connection manual (FUNCTION)(B-63943EN-1_CHAPTER2.) 1. The description of “Start lock signal STLK” has been added before the “All axes Interlock signal *IT”. 2. The description of “Interlock signal fo
  • Page 51.1 START LOCK/INTERLOCK General These signals disable machine movement along axes. When any of these signals is activated during movement, tool movement along the affected axis (or axes) is decelerated, then stopped. Signal Start lock signal STLK [Classification] Input signal [Function] Thi
  • Page 6All axes Interlock signal *IT [Classification] Input signal [Function] This signal is used to inhibit the machine from moving, and is effective regardless of the selected mode. [Operation] When the *IT signal is “0”, the axis movement is decelerated and stopped. In automatic operation, block
  • Page 7NOTE The overtravel distance of the motor after turning *IT to “0” is represented by the following formula. Qmax = Fm×1/60×(A/1000+Tc/1000+Ts/1000) Qmax : Overtravel quantity[mm or inch] Fm : Feedrate[mm/minor inch/min] Tc : Cutting time constant [ms] Ts : Servo time constant(Ts=33ms normally) A : P
  • Page 8NOTE In the T series, when bit 4 (DAU) of parameter No. 3003 is 0, a directional interlock for each axis is applied only during manual operation. To allow a directional interlock for each axis also during automatic operation, set bit 4 (DAU) of parameter No. 3003 to 1. Block start interlock signal *
  • Page 9Signal address #7 #6 #5 #4 #3 #2 #1 #0 Gn007 STLK Gn008 *BSL *CSL *IT Gn130 *IT8 *IT7 *IT6 *IT5 *IT4 *IT3 *IT2 *IT1 Gn132 +MIT8 +MIT7 +MIT6 +MIT5 +MIT4 +MIT3 +MIT2 +MIT1 Gn134 -MIT8 -MIT7 -MIT6 -MIT5 -MIT4 -MIT3 -MIT2 -MIT1 X004 -MIT2 +MIT2 -MIT1 +MIT1 #2 #2 #2 #2 X013 -MIT2 +MIT2 -MIT1 +MIT1 #3 #3
  • Page 10Parameter #7 #6 #5 #4 #3 #2 #1 #0 3003 DAU DIT ITX ITL DIT ITX ITL [Input type] Parameter input [Data type] Bit path #0 ITL Interlock signal 0:Enabled 1:Disabled #2 ITX Interlock signals for each axis 0:Enabled 1:Disabled #3 DIT Interlock for each axis direction 0:Enabled 1:Disabled #4 DAU If bit 3
  • Page 11#7 #6 #5 #4 #3 #2 #1 #0 5009 GSC [Input type] Parameter input [Data type] Bit path NOTE When this parameter is set, the power must be turned off before operation is continued. #0 GSC Specifies from which the offset write signal is to be input for the direct input of tool offset value measurement B f