EDT
DATE
FANUC Series 16i/18i-MB/TB
Simple spindle synchronous control
with any spindles
A-78964E
9/10
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
5. Diagnosis screen
418
Motion error of 1
st
serial spindle
420
Motion error of 2
nd
serial spindle
422
Motion error of 3
rd
serial spindle
424
Motion error of 4
th
serial spindle
These diagnoses show motion error of each serial spindle. The unit of
data is detection unit of the spindle at each spindle mode.
425
Synchronization error when 1
st
spindle is slave
426
Synchronization error when 2
nd
spindle is slave
427
Synchronization error when 3
rd
spindle is slave
428
Synchronization error when 4
th
spindle is slave
These diagnoses show absolute value of synchronization error during
simple spindle synchronous control.
The unit of data is detection unit of the spindle at each spindle mode.
When spindles are spindle mode, these diagnoses data become “0”.