EDT
DATE
FANUC Series 16i/18i-MB/TB
Simple spindle synchronous control
with any spindles
A-78964E
8/10
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
4826
Permissible error pulses when 1
st
spindle is slave
4827
Permissible error pulses when 2
nd
spindle is slave
4828
Permissible error pulses when 3
rd
spindle is slave
4829
Permissible error pulses when 4
th
spindle is slave
Data type : Word
Data unit : Pulse
Data range : 0 to 32767
Specify permissible error pulses between master spindle and slave spindle in
simple spindle synchronous control.
NOTE1) It is available only when the parameter SSY (No.3704#5) is 1.
NOTE2) These parameters are for outputting synchronous error monitoring
signals SYCAL1 to SYCAL4<F043#0 to F043#3>.
These signals will turn “1” when the synchronous error (absolute
value) between master and slave spindle exceed the specified value.