EDT
DATE
FANUC Series 16i/18i-MB/TB
Simple spindle synchronous control
with any spindles
A-78964E
7/10
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
4. Parameters
#7 #6 #5 #4 #3 #2 #1 #0
3704
SSY
Data type: Bit
SSY Enhanced simple spindle synchronous control is:
0: disabled
1: enabled
You can select any pair for simple spindle synchronous control out of 1st to 4th
spindles. Master for each slave is specified in the parameters No.4821 to 4824.
NOTE1) It is available only for serial spindles.
NOTE2) When this parameter is set, power must be turned off before
operation is continued.
4821
Master spindle for 1st spindle
4822
Master spindle for 2nd spindle
4823
Master spindle for 3rd spindle
4824
Master spindle for 4th spindle
Data type : Byte
Specify master spindle for each slave spindle in simple spindle synchronous
control.
EXAMPLE) When specifying 2nd spindle as master and 3rd spindle as slave, the
setting of the parameters is as follows.
No.4821 = 0
No.4822 = 0
No.4823 = 2
No.4824 = 0
NOTE1) It is available only when the parameter SSY (No.3704#5) is 1.
NOTE2) When this parameter is set, power must be turned off before
operation continued.