8. CONNECTORS
B–65142E/04
DESCRIPTIONS FOR α series
88
Connectors for α3 to α40
Motor Type For Power For Signal For Brake
α3/3000, α6/2000
α6/3000
αM6/3000, αM9/3000,
αL6/3000, αL9/3000,
αC3/2000, αC6/2000
H/MS3102A18–10P–D–T (10)
JL04V–2E10SL–3PE–B
(Japan Aviation Electronics
Industry)
α3/3000HV
α6/3000HV
αM6/3000HV
αM9/3000HV
(Hirose Electric)
H/MS3102A10SL–4P
(Hirose Electric)
α12/2000, α12/3000
α22/1500, α22/2000
α30/1200
αC12/2000, αC22/1500
H/MS3102A20–29PCW4 (10)
JL04V–2E10SL–3PE–B
(Japan Aviation Electronics
Industry)
α12/3000HV,
α22/3000HV
α30/3000HV
α40/2000HV
αM22/3000HV
αM30/3000HV
αM40/3000HV
JL04HV–2E22–22PE–B
(Japan Aviation Electronics
Industry)
(Hirose Electric)
H/MS3102A10SL–4P
(Hirose Electric)
α22/3000, α30/2000
α30/3000, α40/2000
α40/2000FAN
αM22/3000, αM30/3000,
αM40/3000,
αM40/3000FAN,
αL25/3000, αL50/2000
JL04V–2E24–10PE(G)–B
(Japan Aviation Electronics
Industry)
JL04V–2E10SL–3PE–B
(Japan Aviation Electronics
Industry)
Fan connectors
Motor Type For Fan
α40/2000FAN
αM40/3000FAN
JL04V–2E10SL–3PE–B
(Japan Aviation Electronics
Industry)
α300, α400
H/MS3102A18–10P–D–T(10)
(Hirose Electric)
CAUTION
1 The motors should be installed with their connector facing downward as long as possible.
When it is impossible to install a motor in this position, allow slack in the cable to keep liquids
such as a dielectric fluid from going along the cable into the cable or motor. If there is a
possibility that the motors and connectors get wet, provide a cover to protect them.
2 If a motor is not connected to the earth ground through the machine (frame), connect the motor
grounding point and the amplifier grounding point to absorb noise using a 1.25 mm
2
or larger
conductor other than the grounding conductor in the power cable. Keep the grounding
conductor as far from the power cable as possible.