B–65142E/04
8. CONNECTORSDESCRIPTIONS FOR α series
89
FANUC can provide TÜV–approved connectors for models α1, and α2.
The table below lists the specifications of connector kits. The connectors
used in models α1 and α2 are dripproof in an engaged position.
Motor model Power cable Signal cable
(straight type)
Connector kit
specifications
176346–8 (AMP Japan)
A06B–6050–K121
(FANUC specification)
HDAB–15S [connector]
HDAW–15–CV
[waterproof cover]
(Hirose Electric)
A06B–6050–K115
(FANUC specification)
Applicable wire
size (Note1)
AWG#18 to AWG#16 AWG#20 (maximum)
Insulation exter-
nal diameter
(Note 2)
f1.8 to 2.8 Not specified
Compatible cable
O.D.
f10.4 to 11.4 f8.4 to 9.2 Water proof:
f10.4 to 11.2
CAUTION
1 AMP Japan connector contacts used in the power cable for
the α1 and α2 are crimp type. Be careful about the
applicable wire. The size of conductors used must meet the
following requirements so that they carry the required
current.
α1 and 2 power cables: AWG#18 to 16
α1 and α2 signal cables: AWG#20 for +5V, 0V, 6VA,
and 0VA, and AWG#24 or
greater for the others
2 For α1 and α2 power cables, select the external diameter
that matches the cable clamp applicable range (10.4 to 11.4
mm
2
) in order to secure TUV approval and waterproof
performance. (See above table)
NOTE
For crimp contacts, insulations as well as wires are crimped.
So, they must meet the size requirements listed above. An
insulation smaller than those listed here may also be used
depending on the wire and tool used. Contact AMP Japan
for details.
8.2
CONNECTORS ON
THE CABLE SIDE
(MODELS a1 AND a2)
8.2.1
Connector Kit
Specifications