B–65142E/04
5. CONDITIONS FOR APPROVAL
RELATED TO THE IEC34
STANDARD
DESCRIPTIONS FOR THE α series
65
The motors can be mounted by the following methods.
IMB5: Flange mounting with the shaft facing sideways (from the rear)
IMV1: Flange mounting with the shaft facing upward (from the rear)
IMV3: Flange mounting with the shaft facing downward
(from the rear)
The heat protection type is as listed below:
1: Temperature rise limit category 1 for heat protection
2: Stop only at stage 1 (no warning)
2: Protection for gradual and abrupt overload
T P 2 1 1
For details on EMC compliance authorization, refer to the separate
manual “Compliance with EMC Directives”
5.4.5
Mounting Method
(IEC34–7)
5.4.6
Heat Protection
(IEC34–11)
Remarks