9. COOLING FAN
B–65142E/04
DESCRIPTIONS FOR THE α series
100
Motor Type α40 with Fan
Input Voltage [V]
Single–phase
200 VAC
Single–phase
230 VAC
Rated Current [A] 0.64"0.06 0.74"0.06
Surge Current [A] 1.06"0.1 1.22"0.1
Protection Circuit Setting
Temperature [°C]
135
Protection Type (IEC34–5) IP00
Rated current(Arms)
Motor Type Input voltage
50Hz 60Hz
αM40/3000 (with fan) 200V (Single–phase) 0.25 Arms 0.23Arms
α300/2000
α400/2000
200V (Three–phase) 0.25 Arms 0.35Arms
α1000/2000HV 200V (Three–phase) 0.75 Arms 0.75Arms
Motor Type Receptacle Connector
α40 with Fan
JL04V–2E10SL–3PE–B (Japan
Aviation Electronics Industry)
α300, α400
H/MS3102A18–10P–D–T(10)
(Hirose Electric)
* 1 Standard brake connectors are used as fan connectors for the α40/αM40.
* 2 α3–class power connectors are used as fan connectors for the α300/α400.
The user must prepare connector cables referring to the following
specifications.
Item Specification
Cable plug connector
For details, see the brake and fan connector
specifications in “8.3 Cable Connector
Specifications.”
Recommend Lead
Diameter (conductor
diameter)
1 mm
2
(AWG18 or equivalent) max.
9.1
COOLING FAN
SPECIFICATIONS
9.2
MOTOR CONNECTOR
SPECIFICATIONS
9.3
ABOUT CONNECTOR
CABLES
α40/2000 with fan,
αM40/3000 with fan,
α300/2000, α400/2000,
α1000/2000HV