B-70314EN/02 3.INSTALLATION
- 63 -
3.6 WATER CONNECTION
3.6.1 Chiller
Make the cooling water re-circulate in the closed loop using a chiller
unit.
The cooling requirements of the chiller are as below.
(1) Chiller capacity
Type Capacity
C1000-E > 11KW
C2000-E > 22.1KW
C4000-E > 44.2KW
C5000-E > 55KW
C6000-E > 66KW
(2) Temperature control range 20 to 30°C
(3) Temperature accuracy ±1°C
(4) Water pressure 0.5Mpa or less
(5) Heat exhaust Water cooling or air cooling
(6) Attachment
• Water filter
• Water valve
• Flow switch
• Interface to externally switch of chiller
• Contact interface to send signal of normal operation of chiller
(CLRDY)
NOTE
Output the signal of "contact on" when everything
is normal with cooling water flow rate, temperature,
water level, overheat switch of chiller, high and low
pressure switch, over-current relay, etc.