Connection of Ethernet Connector Panel Additional Manual Page 4

Additional Manual
EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
3
/
6
DESCRIPTIONDESIG.DATE
Connection of Ethernet Connecto
r
Panel
A
-65563EN/01
3. Connection of Ethernet Connector Panel
CNC Ethernet Connector Panel
Cable connection
(*1)When DC24V is used at CD51, CPD20 connect to DC24V power supply. Do not connect when it is
unnecessary.
CD38x
1 TPTX
2 TPTX
3 TPRX
4
5
6 TPRX
7
8
CD51
1 TPTX
2 TPTX
3 (0V)
4 (+24V)
5 TPRX
6 TPRX
7 (+24V)
8 (0V)
CPD20
1 (+24V)
2 (0V)
3
CD38
A
ttached cable
24V input (*1)
FG
TPTX+
TPTX-
TPRX+
TPRX-
1
2
3
6
4
5
1
2
5
6
3
4
TPTX+
TPTX-
TPRX+
TPRX-
(0V)
(+24V)
(+24V)
(0V)
CD38
(RJ-45)
CD51
CPD20
(+24V)
(0V)
1
2
SHIELD
Grounding
FG

Contents Summary of Connection of Ethernet Connector Panel Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) NO.TMN 05/121E Date: Dec. 19, 2005 General Manager of CNC Laboratory Connection of Ethernet Connector Panel 1. Communicate this report to: ○ Your information ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON ○ Machine tool builder Sales agency End user 2. Summary for Sales D
  • Page 2Ethernet Connector Panel Ethernet Connector Panel enables user to connect/disconnect Ethernet cable at the front panel of the cabinet with ease. 1. Specification Name Specification A02B-0303-C194 with 1m cable Ethernet Connector Panel A02B-0303-C195 with 2m cable A02B-0303-C196 with 5m cable A02B-03
  • Page 3CAUTION Before attaching or removing cables, power off the CNC main unit, and confirm that the power is off. Ask the respective manufacturers for explanations about how to build a network and about conditions for using units (such as a media converter, hub, transceiver, and cable) other than the CNC
  • Page 43. Connection of Ethernet Connector Panel CNC Ethernet Connector Panel CD38x CD51 CD38 1 TPTX+ 1 TPTX+ Attached cable 2 TPTX- 2 TPTX- 3 TPRX+ 3 (0V) 4 4 (+24V) 5 5 TPRX+ 6 TPRX- 6 TPRX- 7 7 (+24V) 8 8 (0V) CPD20 1 (+24V) 24V input (*1) 2 (0V) 3 FG Cable connection CD38 (RJ-45) CD51 TPTX+ 1 1 TPTX+ T
  • Page 54. Connection of Ethernet Cable for Connector Panel Ethernet Connector Panel CD51 Peripherals side 1 TPTX+ connector CD51 2 TPTX- PC or HUB (line 3 (0V) concentrator) 4 (+24V) 5 TPRX+ 6 TPRX- 7 (+24V) 8 (0V) Cable connection [Cross cable] Peripherals CD51 side connector 1 3 TPTX+ TPRX+ TPTX- 2 6 TPR
  • Page 6・Recommended cable side connector (note1) CD51 side: JB5DT08YN121 (Japan Aviation Electronics) Peripheral side: TMP21P-88P (Hirose Electric) ・Recommended cable conductor : A66L-0001-0453 ・Maximum cable length: 40m (in case of recommended cable) Do not make the cable longer than necessary. ・Recommend
  • Page 75. Dimensions of Ethernet Cable for Connector Panel 2 mm 80 mm 14 mm 35 mm 125 mm Crimp terminal M4 Space for the connector Dashed line: Area for packing attachment panel cover 4-M 70 mm 3 80 mm 115 mm 64 mm 123 mm 109 mm Space for the connector panel cover and cable 78 mm 110 mm Panel cut drawing W