PROGRAMMING18. SPECIFYING THE LASER FUNCTION
B–63194EN/02
326
15090 Minimum power specification value
[Data unit] W
[Data range] 0 to 7000
Minimum clamp value for the power specification value that corresponds
to Mmin. If the power specification value calculated from the current
feedrate is less than the value set for this parameter, clamping is performed
with this value.
15091 Minimum pulse frequency
[Data unit] Hz
[Data range] 5 to 2000
Minimum clamp value for the pulse frequency that corresponds to Mmin
in Fig 18.3. If the frequency calculated from the current feedrate is less
than the value set for this parameter, clamping is performed with this
value.
15092 Minimum pulse duty
[Data unit] %
[Data range] 0 to 100
Minimum clamp value for the pulse duty that corresponds to Mmin in Fig
18.3. If the duty calculated from the current feedrate is less than the value
set for this parameter, clamping is performed with this value.
15094 Power control filter time constant
[Unit of data ] ms
[Valid data range] 8 to 32767
This parameter specifies a time constant for the primary delay filter used
to delay the power command for synchronization with machine feed.
The primary delay filter is expressed as follows:
O
n
+ O
n–1
) (I
n
–O
n–1
)
Ts
Tc
Ts: 8 ms (sampling time)
Tc: To be set in this parameter (time constant)
#7
EGM15096
#6 #5 #4 #3 #2
PCD
#1
PCF
#0
PCP
PCP Specifies whether to control the power specification value with the
feedrate.
0 : Does not control the value.
1 : Controls the value.
PCF Specifies whether to control the pulse frequency with the feedrate.
0 : Does not control the frequency.
1 : Controls the frequency.