Series 30i-Model A, Automatic Data Backup Function Additional Manual Page 3

Additional Manual
A-79488E
Title
Draw
No.
Ed. Date Design Description
Date Jun.05.’04 Design. Apprv.
3/7
Page
FANUC Series 30i-MODEL A
Automatic data backup function
- Automatic data backup at every power-on
When the power is turned on, the CNC data can be automatically backed up.
The following settings are necessary for this function.
- Bit 0 (ABP) of parameter No.10340 set to 1.
- Parameter No.10342 set to 1 or more.
- When NC program and NC program folder is backed up, Bit 2 (AAP)
parameter No.10340 set to 1.
- Automatic data backup at power-on every specified days
When the power is turned on after specified days progress from previous
backup, the CNC data can be automatically backed up.
The following settings are necessary for this function.
- Setting of Automatic data backup at every power-on
- Parameter No.10341 set to days of backup interval.
- Manual Backup during emergency stop
When the backup operation is executed in emergency stop, the CNC data can
be backed up. The backup can be executed at arbitrary timing such as
weekend and machining preparation completion.
The following settings are necessary for this function.
- Parameter No.10342 set to 1 or more.
- When NC program and NC program folder is backed up, Bit 2 (AAP)
parameter No.10340 set to 1.
[Operation procedure]
1. Set the emergency stop.
2. Bit 7 (EEB) of parameter No.10340 set to 1. The backup starts by this
operation. When the backup starts, this parameter becomes 0.
3. The execution can be confirmed by diagnose No.1016 on the diagnosis
screen.
Note
When the data is updated while backup, the CNC data
might be not the same as the backup data at start of
backup. When the CNC data is updated while the
emergency stop, please confirm executing automatic
data backup signal ATBK and execute appropriate
processing for not changing the CNC data.
- Execution status of backup
In the backup at power-on, the exectution status is display by ten ‘.’. When
the backup is completed, ‘AUTO BACKUP : ……….END’ is displayed.
And, the following states can be confirmed on the diagnosis screen.
- Bit 0 (AEX) of parameter No.1016 : Backup is Executing
- Bit 6 (ACM) of parameter No.1016 : Backup was completed.
- Bit 7 (ANG) of parameter No.1016 : The error occurred.
- Bit1-3 (DT1-3) of of parameter No.1016 : Updated backup data

Contents Summary of Series 30i-Model A, Automatic Data Backup Function Additional Manual

  • Page 1FANUC Series 30i-MODEL A Automatic data backup function Specifications FANUC Series 30i-MODEL A Title Automatic data backup function Draw A-79488E No. Ed. Date Design Description Page 1/7 Date Jun.05.’04 Design. Apprv.
  • Page 2Outline The data in FROM/SRAM of CNC is automatically backed up to FROM that the battery is unnecessary, and the data can be restored if necessary. When the CNC data disappears by an unexpected situation such as a dead battery, the CNC data can be easily restored. Up to three generations of backup d
  • Page 3- Automatic data backup at every power-on When the power is turned on, the CNC data can be automatically backed up. The following settings are necessary for this function. - Bit 0 (ABP) of parameter No.10340 set to 1. - Parameter No.10342 set to 1 or more. - When NC program and NC program folder is
  • Page 4- Keeps initial backup data Initial backup data can be kept in FROM. For example, the state the shipment and after the Machine adjustment is stored as initial backup data. The number of backup data of parameter No.10342 should set two or more. And the first backup data is the initial backup data. Th
  • Page 5Signal for executing automatic data backup ATBK [Classification] Output signal [Function] This signal becomes 1 while executing the automatic data backup. When the CNC data is updated while the emergency stop, please confirm executing automatic data backup signal ATBK and execute appropriat
  • Page 610341 Interval of periodic automatic data backup at power-on [Input type] Parameter input [Data type] Byte [Valid data range] 0 to 365 This parameter sets backup interval by days when the periodic automatic data backup is executed, When the power is turned on after specified days progress from previ
  • Page 7NOTE Note 1. The value which can be set to parameter No.10342 has the restriction by the program capacity, the SRAM capacity, and the using FROM/SRAM module. 2. Please do not turn off the power of CNC during backing up and restoring. FANUC Series 30i-MODEL A Title Automatic data backup function Draw