A-79488E
Title
Draw
No.
Ed. Date Design Description
Date Jun.05.’04 Design. Apprv.
5/7
Page
FANUC Series 30i-MODEL A
Automatic data backup function
Signal for executing automatic data backup ATBK<F0520#0>
[Classification] Output signal
[Function] This signal becomes 1 while executing the automatic data backup. When the
CNC data is updated while the emergency stop, please confirm executing
automatic data backup signal ATBK and execute appropriate processing.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
F0520 ATBK
Parameters
#7 #6 #5 #4 #3 #2 #1 #0
10340 EEB EIB AAP ABI ABP
[Input type] Parameter input
[Data type] Bit
# 0 ABP Automatic data backup at every power-on is
0 : Invalid
1 : Valid
# 1 ABI Keeping initial backup data is
0 : Invalid
1 : Valid
# 2 AAP Backup of NC program and NC program folder is
0 : Invalid
1 : Valid
# 6 EIB In next CNC power-on, initial backup data is:
0 : Not updated
1 : Updated
Note
When this parameter is used, set 2 or more the
parameter No.10342, and set 1 bit1 (ABI) of the
parameter No.10340.
# 7 EEB Manual Backup during emergency stop is
0 : Not executed
1 : Executed
Note
When this parameter is used, set 1 or more the
parameter No.10342.