Series 30i-Model A, Automatic Data Backup Function Additional Manual Page 4

Additional Manual
A-79488E
Title
Draw
No.
Ed. Date Design Description
Date Jun.05.’04 Design. Apprv.
4/7
Page
FANUC Series 30i-MODEL A
Automatic data backup function
- Keeps initial backup data
Initial backup data can be kept in FROM. For example, the state the
shipment and after the Machine adjustment is stored as initial backup data.
The number of backup data of parameter No.10342 should set two or more.
And the first backup data is the initial backup data.
The following settings are necessary for this function.
- Bit 1 (ABI) of parameter No.10340 set to 1.
- Parameter No.10342 set to 2 or more.
- When NC program and NC program folder is backed up, Bit 2 (AAP)
parameter No.10340 set to 1.
[Operation procedure]
1. Bit 6 (EIB) of parameter No.10340 set to 1.
2. Turn off the power then turn on the power. The first backup data is
automatically updated at power-on, and Bit 6 (EIB) of parameter
No.10340 becomes 0.
The 2nd backup data and the 3rd backup data is updated by the methods of
backup.
- Parity check
The parity check is executed before the backup. If the error is detected, the
backup is not executed.
- Restore of backup data
The backup data of FROM is restored by the following operations on BOOT
SYSTEM.
1. When "7. SRAM DATA UTILITY” of the TOP menu is selected on
BOOT SYSTEM, the following menu is displayed. Please select 3.
2. When data is selected from the following menus, the restore is executed.
3. Please select end menu of BOOT SYSTEM.
Signal
SRAM DATA UTILITY
1.SRAM BACKUP ( CNC -> MEMORY CARD )
2.SRAM RESTORE ( MEMORY CARD -> CNC )
3.AUTO BKUP RESTORE ( FROM -> CNC )
4. END
A
UTO BACKUP DATA RESTORE
1. BACKUP DATA1 yyyy/mm/dd **:**:**
2. BACKUP DATA2 yyyy/mm/dd **:**:**
3. BACKUP DATA3 yyyy/mm/dd **:**:**
4. END

Contents Summary of Series 30i-Model A, Automatic Data Backup Function Additional Manual

  • Page 1FANUC Series 30i-MODEL A Automatic data backup function Specifications FANUC Series 30i-MODEL A Title Automatic data backup function Draw A-79488E No. Ed. Date Design Description Page 1/7 Date Jun.05.’04 Design. Apprv.
  • Page 2Outline The data in FROM/SRAM of CNC is automatically backed up to FROM that the battery is unnecessary, and the data can be restored if necessary. When the CNC data disappears by an unexpected situation such as a dead battery, the CNC data can be easily restored. Up to three generations of backup d
  • Page 3- Automatic data backup at every power-on When the power is turned on, the CNC data can be automatically backed up. The following settings are necessary for this function. - Bit 0 (ABP) of parameter No.10340 set to 1. - Parameter No.10342 set to 1 or more. - When NC program and NC program folder is
  • Page 4- Keeps initial backup data Initial backup data can be kept in FROM. For example, the state the shipment and after the Machine adjustment is stored as initial backup data. The number of backup data of parameter No.10342 should set two or more. And the first backup data is the initial backup data. Th
  • Page 5Signal for executing automatic data backup ATBK [Classification] Output signal [Function] This signal becomes 1 while executing the automatic data backup. When the CNC data is updated while the emergency stop, please confirm executing automatic data backup signal ATBK and execute appropriat
  • Page 610341 Interval of periodic automatic data backup at power-on [Input type] Parameter input [Data type] Byte [Valid data range] 0 to 365 This parameter sets backup interval by days when the periodic automatic data backup is executed, When the power is turned on after specified days progress from previ
  • Page 7NOTE Note 1. The value which can be set to parameter No.10342 has the restriction by the program capacity, the SRAM capacity, and the using FROM/SRAM module. 2. Please do not turn off the power of CNC during backing up and restoring. FANUC Series 30i-MODEL A Title Automatic data backup function Draw