A-79488E
Title
Draw
No.
Ed. Date Design Description
Date Jun.05.’04 Design. Apprv.
6/7
Page
FANUC Series 30i-MODEL A
Automatic data backup function
10341 Interval of periodic automatic data backup at power-on
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 365
This parameter sets backup interval by days when the periodic automatic
data backup is executed, When the power is turned on after specified days
progress from previous backup, the CNC data can be automatically backed
up. If 0 is specified in this parameter, this function is not performed.
10342 Number of backup data
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 3
This paramer sets the number of backup data. If 0 is specified in this
parameter, this function is not performed.
Diagnosis
The execution status of backup can be confirmed in diagnosis screen.
#7 #6 #5 #4 #3 #2 #1 #0
1016 ANG ACM DT3 DT2 DT1 AEX
# 0 AEX Automatic data backup is:
0 : Not executing
1 : Executing
# 1 DT1 In previous backup,
0 : Data 1 is not updated.
1 : Data 1 is updated.
# 2 DT2 In previous backup,
0 : Data 2 is not updated.
1 : Data 2 is updated.
# 3 DT3 In previous backup,
0 : Data 3 is not updated.
1 : Data 3 is updated.
# 6 ACM Automatic data backup was
0 : Not executed
1 : Executed
# 7 ANG In automatic data backup,
0 : The error does not occur.
1 : The error occurred.