CDD1
FAP–50–1
CDD2
FAP–50–1
Cable
Connection Unit 1 Connection Unit 2
B–63783EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
177
(b)Between CDD1 and CDD2
A01 0V B01 0V A01 0V B01 0V
A02
B02 A02 B02
A03
B03 A03 B03
A04 0V B04
A04 0V B04
A05 B05
A05 B05
A06
B06 0V A06 B06 0V
A07 *D7 B07 *D6 A07 *D7 B07 *D6
A08 *D5 B08 *D5 A08 *D5 B08 *D5
A09 0V B09 *D3 A09 0V B09 *D3
A10 *D2 B10 *D1 A10 *D2 B10 *D1
A11 *D0 B11 0V A11 *D0 B11 0V
A12 0V B12 0V A12 0V B12 0V
A13 AU B13 A4 A13 AU B13 A4
A14 A3 B14 0V A14 A3 B14 0V
A15 A2 B15 A1 A15 A2 B15 A1
A16 A0 B16 0V A16 A0 B16 0V
A17 *OE B17 0V A17 *OE B17 0V
A18 0V B18 0V A18 0V B18 0V
A19 *DVWE B19 0V A19 *DVWE B19 0V
A20 0V B20
A20 0V B20
A21 0V B21 0V A21 0V B21 0V
A22 *ALRO B22 0V A22 *ALRO B22 0V
A23 *CLR B23 EN A23 *CLR B23 EN
A24
B24 0V A24 B24 0V
A25 *ASIO B25
A25 *ASIO B25
The following cable is available.
Name Ordering code Length
Cable A02B–0072–K818 150mm
Maximum wire length: 1 m
Connectors at the ends of the cable:
FAS–50–17 (A63L–0001–0209#50)