When we set parameter 1902, we mentioned that we had to manually set parameters 1936 and
1937 as well. These two parameters apply only when using separate feedback devices. Since we
don’t have any in our example setup, we’ll just leave these set to their default value of zero.
1936 X 0
Z0
C0
1937 X 0
Z0
C0
Enable Write Protect (Optional)
Now that you have set all of the startup parameters, you can choose to turn off the Parameter
Write Enable (PWE) bit and finally get rid of the alarm:
100 PARAMETER WRITE ENABLE
As we mentioned in Chapter 2, this is the built-in software write protect feature which will prevent
accidental changes to parameter values. However, since you will still need to enter values for the
parameters which are specific to your machine’s application, we recommend that you turn off
PWE after these have all been entered. If you turn off PWE, please remember that you cannot
change any parameter values until it is turned back on.