8 Special Keep Relays
K0.0 Reference Return Completed Check Bypass
For Cycle Start
0: Reference Done Checked
1: Reference Done Not Checked
K0.1 Machine Door Closed/Open Switch Bypass
For Spindle Running
0: Door Switch Checked
1: Door Switch Not Checked
K0.2 Thermic Motor Relay Bypass 0: Relay Checked
1: Relay Not Checked
K0.3 Spindle Running Bypass For Cycle Start 0: Spindle Running Checked
1
: Spindle Running Not Checked
K0.4 Machine Door Closed/Open Switch Bypass
For Cycle Start
0: Door Switch Checked
1: Door Switch Not Checked
K0.6 Tails Stock Z+ Limit Switch 0: Tail Stock Switch Checked
1: Tail Stock Switch Ignored
K1.0 Keep Relay to Protect Programs/Offsets 0: Not Protected
1: Protected (Do not set)
K1.1 Auxiliary Function Look 0: Not Looked
1: Looked (Do not set)
K1.2 Single Block Mode 0: Normal
1: Single Block (Do not set)
K5.5 If the T-Code memorised together with cycle
does not correspond to active tool,
0: Cycle stopped by Alarm
1: Cycle on hold restart possible
K5.6 Gear Check if Spindle Speed is Saved to
Cycle (Set to 1 if machine has no gears)
0: Gear is Checked
1: Gear is Not Checked