9 Output Signals
Address Signal Description Remarks
Y0.0 Lubrication Device 0: No Effect
1: Lubrication Device Running
Y0.1 Spindle Running CW 0: No Effect (Message if
Cycle Start Pressed + Cycle Start
Blocked)
1: Spindle Running CW
Y0.2 Spindle Running CCW 0: No Effect (Message if
Cycle Start Pressed + Cycle Start
Blocked)
1: Spindle Running CCW
Y0.3 CNC OK 0: CNC Not Ready
1
: CNC Ready
Y0.4 Coolant Pump Running 0: No Effect
1: Coolant Pump Running
Y0.5 Cycle Running 0: No Effect
1: Cycle Running Check Lamp ON
Y0.6 Spindle stop 0: No Effect
1: Spindle Stop