B–63130EN/01
11. SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
61
11
SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
Address
16800 Nibbling pitch for first stage (metric input)
16801 Nibbling pitch for second stage (metric input)
16802 Nibbling pitch for first stage (inch input)
16803 Nibbling pitch for second stage (inch input)
Data type: Two–word
Units of data:
Increment system IS–A IS–B Units
Metric input 0.01 0.001 mm
Inch input 0.001 0.0001 inch
Valid data range: 0 to 99999999
When using three–stage switching for constant positioning time control
for the X– and Y–axes during nibbling, use these parameters to set the
nibbling pitches (common to the X– and Y–axes).
The value set for the first stage must be smaller than that set for the second
stage.
If the third stage is not used, set 99999999 for the second stage.
Address
16804 First stage positioning time for X–axis
16805 Second stage positioning time for X–axis
16806 Third stage positioning time for X–axis
16807 First stage positioning time for Y–axis
16808 Second stage positioning time for Y–axis
16809 Third stage positioning time for Y–axis
Data type: Byte
Units of data: msec
Valid data range: 0 to 254
When using three–stage switching for constant positioning time control
for the X– and Y–axes during nibbling, use these parameters to set the
positioning times.