A-79344E
Title
Draw
No.
Ed. Date Design Description
Date
Jan.06.’04 Design. Apprv.
18/24
page
FANUC Series 30i-MODEL A
Input of tool offset value measured B
#7 #6 #5 #4 #3 #2 #1 #0
5004 TSI
[Input type] Parameter input
[Data type] Bit path
# 3 TSI When the tool offset measurement value direct input B function is used,
touch sensor contact detection is based on.
0: Four-contact input
1: One-contact input
#7 #6 #5 #4 #3 #2 #1 #0
5005 QNI
[Input type] Parameter input
[Data type] Bit path
# 5 QNI The function to input offset value measured B
0: Does not automatically select the tool offset number
1: Automatically selects a tool offset number
#7 #6 #5 #4 #3 #2 #1 #0
5009 GSC
[Input type] Parameter input
[Data type] Bit path
Note
When this parameter is set, the power must be turned off before
operation is continued.
# 0 GSC Specifies from which the offset write signal is to be input for the tool
compensation amount measurement velue direct input B function, as
follows:
0: To be input form the machine.
1: To be input from the PMC.
If axis direction–specific interlock is enabled (bit 3 or parameter No. 3003 (DIT) is
0), its input is also switched from the machine to the PMC.