A-90188E-01 SETTING 1.MODBUS/TCP SERVER FUNCTION
- 24 -
Status
The status is detected by MODBUS/TCP Server function.
Status
STATUS PMC ADDRESS MODBUS Status (1 byte)
MODBUS Status
Bit 0 :Some unrecoverable error occurred in
MODBUS board (Error status).
Bit 1 to Bit 5: Reserved
Bit 6 :The initialization of MODBUS board has been
completed (Normal status).
Bit 7 :MODBUS/TCP function is actually
communicating with one remote client or more
(Normal status).
CAUTION
Keep the following in mind when setting STATUS
ADDRESS and SIZE.
1 Make sure that it does not overlap with the input
data area of MODBUS/TCP Server function.
2 Make sure that it does not overlap with the input
data area of a ladder program.
Soft key
Item Description
ENABLE Specified AREA is used as an I/O area for MODBUS.
(When a cursor is checked with “COMMUNICATE” of
AREA1-3, this soft key is displayed.)
DISABLE Specified AREA is not used as an I/O area for
MODBUS.
(When a cursor is checked with “COMMUNICATE” of
AREA1-3, this soft key is displayed.)