page
Ed. Date Design Description
Date
Jan.07.’04 Design. Apprv.
9 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
#7 #6 #5 #4 #3 #2 #1 #0
12331 G1F G1E G1D G1C G1B G1A G19 G18
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 0 G18 If the PMC group-8(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-8.
1: not transferred to group-8.
# 1 G19 If the PMC group-9(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-9.
1: not transferred to group-9.
# 2 G1A If the PMC group-10(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-10.
1: not transferred to group-10.
# 3 G1B If the PMC group-11(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-11.
1: not transferred to group-11.
# 4 G1C If the PMC group-12(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-12.
1: not transferred to group-12.
# 5 G1D If the PMC group-13(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-13.