page
Ed. Date Design Description
Date
Jan.07.’04 Design. Apprv.
10 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
# 6 G1E If the PMC group-14(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-14.
1: not transferred to group-14.
# 7 G1F If the PMC group-15(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-15.
1: not transferred to group-15.
#7 #6 #5 #4 #3 #2 #1 #0
12332 G27 G26 G25 G24 G23 G22 G21 G20
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 0 G20 If the PMC group-0(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-0.
1: not transferred to group-0.
# 1 G21 If the PMC group-1(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-1.
1: not transferred to group-1.
# 2 G22 If the PMC group-2(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-2.
1: not transferred to group-2.
# 3 G23 If the PMC group-3(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-3.
1: not transferred to group-3.