page
Ed. Date Design Description
Date
Jan.07.’04 Design. Apprv.
11 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
# 4 G24 If the PMC group-4(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-4.
1: not transferred to group-4.
# 5 G25 If the PMC group-5(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-5.
1: not transferred to group-5.
# 6 G26 If the PMC group-6(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-6.
1: not transferred to group-6.
# 7 G27 If the PMC group-7(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-7.
1: not transferred to group-7.
#7 #6 #5 #4 #3 #2 #1 #0
12333 G2F G2E G2D G2C G2B G2A G29 G28
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 0 G28 If the PMC group-8(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-8.
1: not transferred to group-8.
# 1 G29 If the PMC group-9(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-9.
1: not transferred to group-9.