5. CONNECTIONS
B–65152E/03
FANUC AC SPINDLE MOTOR α series
64
Sections 8.2.3 of IEC204–1 (EN60204–1), which must be met to acquire
CE marking approval, stipulates that all exposed live conductors of
electric equipment and machines be connected to a protection link circuit.
WARNING
If the connector portion of a motor is exposed to the outside,
its metal portion should be covered with a non–moving
insulation, or the metal shell should be connected to a
protection link circuit using the following connector kit.
` Connector kit: A06B–6050–K121 [FANUC specification]
CAUTION
1 Cables with an external size of 9.9 to 10.9 mm should be
used to provide a sufficient waterproof performance related
to cable clamps.
The number of cable conductors is 1 greater than the
conventional U/V/W/G to provide for the connector shell
protection link circuit, that is 5 conductors.
2 The motor grounding wire (at terminal 4) and connector
shell grounding wire should be bundled with one crimping
terminal and connected to the grounding terminal of the
amplifier. The grounding lines must be indicated in
yellow/green.
CONDITIONS FOR
APPROVAL RELATED TO
THE IEC34 STANDARD