2 - 8 Alpha Series Servo Amplifier Module (SVM) with FSSB - April 1998 GFK-1546
2
Axis Setting Screen
The following item can be set on the Amplifier Setting screen:
Item Name Description
M1 Connector Number of the 1st
Pulse Module
Enter the connector number for the axis using the first pulse
module.
The data range is from 1 to the maximum number of the first
pulse module connector.
0 is set for the axis not using the first pulse module.
If the input value is out of range, the warning "FORMAT
ERROR" occurs.
M2 Connector Number for the 2nd
Pulse Module
Enter the connector number for the axis using the second pulse
module.
The data range is from 1 to the maximum number of the second
pulse module connector.
0 is set for the axis not using the second pulse module.
If the input value is out of range, the warning "FORMAT
ERROR" occurs.
1-DSP 1-DSP Axis
Enter 1 for the Cs contouring control axis.
If a value other than 0 or 1 is entered, the warning "FORMAT
ERROR" occurs.
CS Cs Contour Control Axis
Enter 1 for the Cs contouring control axis.
If a value other than 0 or 1 is entered, the warning "FORMAT
ERROR" occurs.
TNDM Tandem Control Axis When tandem control is used, enter two consecutive numbers, one
odd for a master and one even for a slave. The data range is from
1 to 8. If a value that is out of range is entered, the warning
"FORMAT ERROR" occurs.