Description of Parameters
Parameter No. 1902
No. 7 6 5 4 3 2 1 0
1902 ASIGN FSBMD
Data Type: Bit
Parameter Setting Description
FSBMD 0 Automatic setting mode.
After the axis information is entered on the FSSB Setting screen, parameter
No. 1023, 1905, 1910 - 1919, 1936, and 1937 are set automatically.
1 Manual setting mode.
You must enter parameter No. 1023, 1905, 1910 - 1919, 1936, and 1937
manually.
ASIGN 0 Automatic setting is completed.
1 Automatic setting is not completed.
Note: When the automatic setting is done, this bit automatically becomes 1.
4