GFK-1546 Chapter 3 Setting Parameters 3 - 5
3
Automatic Setting
Under the following conditions, you can use the FSSB Setting screen to set the parameters
automatically:
No. 1902#0=0
No. 1902#1=0
To set the parameters automatically using the FSSB Setting screen, follow this procedure:
1. Set servo axis No. 1023. Then, set the number of the axis to No. 1023 to correspond to the
total number of amplifier axes.
2. Initialize the servo parameters on the Servo Initial Setting screen.
3. Turn power to the CNC OFF and then ON.
4. Press the SYSTEM function key.
5. Press the >> key several times to display the [FSSB] soft key. Then, press the [FSSB]
soft key to display the Amplifier Setting screen.
AMPLIFIER SETTING
NO. AMP SERIES UNIT CUR. [AXIS] NAME
1 A1-L α SVM 40AL [ 1 ] X
2 A1-M α SVM 12A [ 2 ] Y
3 A2-L β SVU 20A [ 3 ] Z
4 A3-L α SVM 40A [ 4 ] A
5 A3-M α SVM 80A [ 5 ] B
7 A4-L α SVM 40AS [ 6 ] C
NO. EXTRA PCB ID
6 M1 A 0008 DETECTOR(4AXES)
8 M2 A 0008 DETECTOR(4AXES)
>
MDI **** *** *** 13:11:56
[ AMP ] [ AXIS ] [MAINTE ] [ ] [(OPRT) ]
6. Enter the axis name for each amplifier on the Amplifier Setting screen.
Note
Do not set the control axis name to 0 or a duplicated value.