FANUC Series 16i-TA
2 CPU 3-path control function
Specifications
A-63406E
08 00.09.01 T.Nakazato Modified (viii)
07 00.06.23 T.Nakazato Modified (vii) H. kochiya
01 97.04.09 T.Nakazato Newly registered T. Masuda
ED. DATE DESIG. DESCRIPTION
TITLE
DRAW.NO.
SHEET
(6) Signals
(a) Spindle command select signals
7 6 5 4 3 2 1 0
G0063 SLSPB
#1
SLSPA
#1
G1063 SLSPB
#2
SLSPA
#2
G2063 SLSPB
#3
SLSPA
#3
[Classification] Input signal
[Function] Selects which spindle receives spindle command of which path.
[Operation]
Spindle command
on path 1
Spindle command
on path 2
Spindle command
on path 3
Spindles
on path 1
SLSPA
#1
=1
SLSPB
#1
=0
SLSPA
#1
=0
SLSPB
#1
=1
SLSPA
#1
=1
SLSPB
#1
=1
Spindles
on path 2
SLSPA
#2
=1
SLSPB
#2
=0
SLSPA
#2
=0
SLSPB
#2
=1
SLSPA
#2
=1
SLSPB
#2
=1
Spindles
on path 3
SLSPA
#3
=1
SLSPB
#3
=0
SLSPA
#3
=0
SLSPB
#3
=1
SLSPA
#3
=1
SLSPB
#3
=1
To control spindles on path 2 by command on path 3, set SLSPA,B
#2
to
(1,1). At this time, if SLSPA,B
#1
or SLSPA,B
#3
are set (1,1), the spindle
on path 1 or path 3 also rotates by command of path 3.
Notice
If both of SLSPA and SLSPB are “0”, spindle command output “0”.