(d) Spindle stop signals
7 6 5 4 3 2 1 0
G0027 *SSTP3
#1
*SSTP2
#1
*SSTP1
#1
G1027 *SSTP3
#2
*SSTP2
#2
*SSTP1
#2
G2027 *SSTP3
#3
*SSTP2
#3
*SSTP1
#3
[Classification] Input signal
[Function] In the multi-spindle function, each spindle on each path can be stopped
individually by these signals.
[Operation]
*SSTP1
#1
1: 0 rpm is not output to the 1
st
spindle on path 1.
0: 0 rpm is output to the 1
st
spindle on path 1.
*SSTP2
#1
1: 0 rpm is not output to the 2
nd
spindle on path 1.
0: 0 rpm is output to the 1
st
spindle on path 1.
*SSTP3
#1
1: 0 rpm is not output to the 3
rd
spindle on path 1.
0: 0 rpm is output to the 3
rd
spindle on path 1.
*SSTP1
#2
1: 0 rpm is not output to the 1
st
spindle on path 2.
0: 0 rpm is output to the 1
st
spindle on path 2.
*SSTP2
#2
1: 0 rpm is not output to the 2
nd
spindle on path 2.
0: 0 rpm is output to the 1
st
spindle on path 2.
*SSTP3
#2
1: 0 rpm is not output to the 3
rd
spindle on path 2.
0: 0 rpm is output to the 3
rd
spindle on path 2.
*SSTP1
#3
1: 0 rpm is not output to the 1
st
spindle on path 3.
0: 0 rpm is output to the 1
st
spindle on path 3.
*SSTP2
#3
1: 0 rpm is not output to the 2
nd
spindle on path 3.
0: 0 rpm is output to the 1
st
spindle on path 3.
*SSTP3
#3
1: 0 rpm is not output to the 3
rd
spindle on path 3.
0: 0 rpm is output to the 3
rd
spindle on path 3.