B–63175EN/03
4. INTERFACE BETWEEN NC AND PMC
303
1 Nonvolatile memory control
#7
K016
#6 #5 #4 #3 #2 #1 #0
MWRTF2 : For checking the writing status in nonvolatile memory
MWRTF1 : Writing status in nonvolatile memory
2 PMC system parameter
The following keep relays are used by the system, therefore they
cannot be used in the sequence program.
#7
K017 or K900
#6 #5 #4 #3 #2 #1 #0
DTBLDSP 0 : The PMC parameter data table control screen is displayed.
1 : The PMC parameter data table control screen is not displayed.
ANASTST 0 : Sampling starts by soft key [EXEC] in the signal waveform display
function.
1 : Sampling starts automatically by power on in the signal waveform
display function.
TRCSTAT 0 : Signal tracing starts by soft key [EXEC] in signal trace function.
1 : Signal tracing starts automatically by power on in signal trace
function.
MEMINP 0 : Data input cannot be done in memory contents display function.
1 : Data input can be done in memory contents display function.
AUTORUN 0 : A sequence program is executed automatically after the power is
turned on.
1 : A sequence program is executed by sequence program soft key.
PRGRAM 0 : Built–in programmer is not used.
1 : Built–in programmer is used.
WARNING
At machine shipment, factory–set this bit to 0. If this bit is
left 1, the operator may stop the ladder by mistake, which
may lead to an accident.
LADMASK 0 : Dynamic display of ladder is executed.
1 : Dynamic display of ladder is not executed.