B–63175EN/03
4. INTERFACE BETWEEN NC AND PMC
317
To return to the sequence program storage screen, press the [ ↑ ] or
[ ↓ ] key.
5. Pressing the [CAN] key displays the PMC programmer menu.
The table below lists the details of the errors which may occur during
storage into F–ROM using the DPL/MDI.
Error message Description
PROGRAM DATAERROR The ladder data in RAM is invalid.
Alternatively, there is no RAM or ROM.
SIZE ERROR The program exceeds the maximum size which
can be written into F–ROM.
OPEN ERROR The OPEN processing has failed.
ERASE ERROR The ERASE processing has failed.
The F–ROM cannot be erased.
Alternatively, the F–ROM is defective.
WRITE ERROR The WRITE processing has failed.
The F–ROM cannot be written.
Alternatively, the F–ROM is defective.
D Method of Inputting/Outputting Ladder
(1)Select ”Diagnose screen” by key in [DGNOS/PARAM] key.
(2)Key in [READ] key or [WRITE] key.
(3)Operate following procedure from Off line programmer.
1. Select F5: [I/O] [INPUT/OUTPUT] from screen of Off line
menu.
2. Select F3: [PMC] from screen of INPUT/OUTPUT menu.
3. Select F1: [DNLOAD] [down load (programmer → RPMC)] or
F2: [UPLOAD] [up load (programmer ← PMC)] from screen
of PMC menu and key in [Enter].
D Method of Inputting Ladder and PMC–Parameter.
(1)Select ”Diagnose screen” by key in [DGNOS/PARAM] key.
(2)Key in [No.] key and optionally key in [File No.].
(3)Key in [READ] key.
NOTE
In case of input PMC–Parameter, it is necessary to set
following conditions.
1 Emergency stop condition, and NC–Parameter PWE=1.
2 Stop condition the Ladder program.
Error details
4.4.8
Input/Output Ladder/
PMC–parameter by
DPL/MDI
Input/Output method to
office programmer
(Fixed 9600bit/sec.)
Input/Output method to
FANUC FLOPPY
CASSETE (Fixed