C.PARAMTER LIST B-70254EN/01
- 68 -
15056 Type of piercing assist gas
Data type: Word
Unit of data:
Range of data: 0 to 7
Set a type of assist gas to be used for piercing.
15057 Return distance
Data type: Two-word
Unit of data:
Setting range IS-A IS-B IS-C Unit
Metric input
0.01 0.001 0.0001 mm
Inch input
0.001 0.0001 0.00001 inch
Range of data: 0 to 65000
Set a return distance from the top of a corner to the next block.
15058 Return feedrate
Data type: Word
Unit of data: mm/min
Range of data: 0 to 9999
Set a return feedrate to be used for movement from the top of a corner
to the next block.
15059 Peak return power value
Data type: Word
Unit of data: W
Range of data: 0 to 7000
Set a peak return power value to be used for movement from the top
of a corner to the next block.
15060 Return frequency
Data type: Word
Unit of data: Hz
Range of data: 5 to 2000
Set a return frequency to be used for movement from the top of a
corner to the next block.
15061 Return duty ratio
Data type: Word
Unit of data: %
Range of data: 0 to 100
Set a return duty ratio to be applied to movement from the top of a
corner to the next block.