B-65202EN102
INSTRUCTION
4. SENSOR
Runout of outer surface of drum
The runout of the outer surface of the
magnetic drum must be 15 Q m or less
Datum plane
CAUTION
Use indicator tip on the surface within 5mm from the ‘7” printed side. If the tip
contact other surface of the drum, magnetic data on the drum will be erased,
Runout of mounting ring
The runout of the sensor mounting ring must
be 20 u m or less.
Datum plane
of mounting ring
Datum plane
of drum
20 p m or less
“Z” side
4.2.2
lnterference(for A860-0382-T121)
Fit the drum of A860-038%T121 by shrink fitting. Use proper interference
shown below according to the maximum rotation speed.
Maximum sqeed(kn-‘)
I nt~*rence{ lu
m)
6000
d 26
- ti 47
8000
@ 27
- d 48
1000
C$ 27
- 6 48
12000
$I 28
- $J 49
15000
f#I 30
- (iI 51
CAUTION
WIf the incorrect interference is chosen, the drum will loosen by centrifugal
force or deform.
WAllowable temperature of the drum is 100°C. Do not heat the drum more
than 100°C.
-61-