A. ACCELERATION TIME
APPENDIX
B65202EN102
A
ACCELERATION TIME
In acceleration, the output of the built-in AC spindle motor is 120% of S2
or S3 rated output.
The acceleration time required for acceleration can be calculated from the
expressions below. As the load torque of the machine is not considered in
this calculation, the actual acceleration time is slightly longer than the
time calculated here.
Acceleration output
Rated output
Nh
Nf Nm
Motor speed (min.‘)
JL
:Load inertia converted into motor shaft &gm2]
J,
:Motor inertia Fgm2]
PO, Pm
:Output &WI
Nb Nf Nm .Mot.nr snwd Imin-11
@ Acceleration time (tl)in the constant torque region (O-i%)
tl=0.01097 X (JL+J,) X Nb2+Pot 1000 [set]
@ Acceleration time (tz) in the constant output region (Nb+Nf)
t2=0.01097 x (JL+J,) X (Nf2-Nb2)t 2Po+ 1000 [set]
@ Acceleration time (t3) in the output reduction region (Nf-Nm)
t3=0.01097 x (JL+J,) X (Nm-Nf)
f (Pm-PO)+ 1000
x {(Nm-Nf)-(Po X Nm-Pm X Nf)+ (Pm-PO) X ln(Pm -PO)} [set]
Total acceleration time (t) from 0 to Nm
t=tl+t2+t3 [secl
-84-