B–63840EN/03
4. DESCRIPTION OF PARAMETERS
141
3627
Pitch error compensation (absolute value) at reference position when a move-
ment to the reference position is made from the direction opposite to the direc-
tion of reference position return
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] –32768 to 32767
Set the absolute value of pitch error compensation at reference position
when a movement to the reference position is made from the negative
direction if the direction of reference position return (bit 5 (ZMI) of
parameter No. 1006) is positive or from the positive direction if the
direction of reference position return is negative.