FANUC Series 16i/18i/21i-MA/MB/TB TOOL MANAGEMENT FUNCTION A-78614EN
2002.08.08 Edition 04
36
Setting of name of the tool life state
Specify the state name of the tool life state ( 0 to 4 ).
G10 L77 P2 ;
N_ ;
P_ R_ ;
P_ R_ ;
;
N_ ;
P_ R_ ;
P_ R_ ;
G11 ;
N : Tool life state ( 0 to 4 )
P : character number ( 1 to 16 )
R : character code ( ASCII )
• To clear the data, 0 is specified.
• The confirmation of a set value is possible only by the tool management
data screen.
• When the name is not registered, "ENABLE" etc. which are a
predetermined value are displayed.
• The displayed name is 16 characters or less. When the name string does
not come up to 16 characters, please register 0 in an empty area. Even the
character immediately before 0 is displayed.
• Please set 0 as a character-code to clear data.
• The data of the character-code is not checked.
• It is possible to register up to 6 characters by normal-width on the standard
tool management screen.
• The predetermined strings are followings.
• 0 : NO-MNG
• 1 : ENABLE
• 2 : ENABLE
• 3: OVER
• 4 : DAMAGE