3.FUNCTIONS DIFFERENT FROM THOSE OF THE M SERIES CNC B-63662EN/01
- 14 -
3.1 EMERGENCY STOP
If an emergency stop occurs when the oscillator is operating, the
oscillator shutter is closed, the laser beam is turned off, the high-
frequency power supply is turned off to stop discharge, and the assist
gas selection signals quit selection, all at the same time the machine
stops.
After the machine is released from the emergency stop state, turning
on the discharge start signal causes the oscillator to operate.
3.2 FEED HOLD
If the feed hold command is issued when the machine is running with
the laser beam turned on, the machine is decelerated to stop, the laser
beam is turned off, the shutter is closed, and the assist gas supply is
stopped.
Pressing the cycle start button starts supplying the assist gas, opens
the shutter, turns on the laser beam, and causes the machine to run
again.
3.3 MACHINE LOCK
Even if laser beam output has been programmed, the machine lock
function causes the laser beam output commands to be ignored and
allows only the machine move commands to be calculated. As a result,
the machine does not move, but the current position display is
updated. If the pierce command G24 is executed, it works as a dwell
command without outputting a laser beam.
3.4 DRY RUN
Even if laser beam output has been programmed, the dry run function
causes the laser beam output commands to be ignored. As a result, the
machine dry-runs with the laser beam turned off. If the pierce
command G24 is executed, it works as a dwell command, because a
laser beam is not output.