B-63662EN/01 6.ASSIST GAS CONTROL
- 23 -
- Format
G32L- ;
L=0 : The shutter is closed, and the assist gas supply is
stopped.
L=1 : The shutter is opened, and the assist gas supply is
started according to cutting condition data.
L=2 : The shutter is opened, and the assist gas supply is
started according to piercing condition data.
This command uses the gas type, pressure, and settling time
specified as cutting condition data in E code format.
(See the description of the cutting condition setting function.)
Flow pattern command
The following pattern of data such as pre-stage pressure and time,
cutting pressure, and post-stage pressure and time is previously
registered as a flow pattern. It can be specified using the Q address.
Cutting pressure
Time
Pre-stage time
Post-sta
e time
Post-stage pressure
Pre-stage pressure
Specifying P≠0 and Q≠0 in the G32 flow pattern command opens the
shutter, outputs the assist gas selection signals, then outputs the assist
gas pressure analog signal according to the flow pattern.
Specifying P=0 or Q=0 in G32 closes the shutter, and causes the assist
gas selection signals to quit selecting an assist gas, then turns off the
assist gas pressure analog signal after the post-stage is generated for
the specified post-stage time.
- Format
G32P-(Q-) ;
The parameters enclosed in parentheses is omissible.
P=gas type :
Specifies the assist gas type.
0 : The shutter is closed, and no assist gas is selected.
1 to 7 : The shutter is opened, and an assist gas is
selected.
T= pattern selection :
Specifies a flow pattern number.