B-64663EN/01 LASER FUNCTION 7.THREE-DIMENSIONAL MACHINING SYSTEM
- 113 -
Reference attitude of the β axis
When the α axis is set to 0° and the β axis is viewed from the +X
direction, the position where the nozzle faces in the -Z direction is 0°.
When +90° rotation from that position is commanded, the β axis
rotates counterclockwise.
Setting differences if the α and β axes are not in their reference positions
If the axes are not in their reference positions, specify the differences
in the appropriate parameters.
By specifying them in the parameters, the CNC performs attitude
control by considering the differences from the reference positions.
The rotation directions can be selected with parameter No. 15601.
The machine zero-degree positions can be offset with parameters Nos.
15601 and 15611.
Coordinate system
The machine coordinates refer to the coordinates (x, y, z) of the fixed
section of the nozzle.
The program coordinates refer to the coordinates (X, Y, Z) of the
nozzle head.
The length of the 1st arm, L1, and the length of the 2nd arm, required
to convert the machine coordinates to program coordinates. Specify
them using the parameters No. 15615 and 15616.
Axis names
Specify the names of the α (4th) and β (5th) axes using parameter No.
1020.
Attitude control mode
In manual operation, mode select signal ALNAXS can be used to
switch between the nozzle head fixing mode and the independent axis
mode. When the ALNAXS signal is set to 0, the machine tool enters
the nozzle head fixing mode. When the ALNAXS signal is set to 1,
the machine tool enters the independent axis mode.
In automatic operation, the machine tool automatically enters the
nozzle head fixing mode regardless of the mode select signal.
In manual reference position return, the machine tool automatically
enters the independent axis mode regardless of the mode select signal.
After reference position return is completed, the attitude control
function is enabled.
In automatic reference position return, the machine tool automatically
operates in the independent axis mode.
Independent axis mode
When the command specifying the α or β axis is issued, only the
specified axis rotates. When the α or β axis is rotated by this
command, the position of the nozzle head is changed. The coordinates
in the incremental coordinate system and workpiece coordinate system
are then changed according to changed coordinates (X, Y, Z) to make
the position of the nozzle head match the coordinate systems.