7.THREE-DIMENSIONAL MACHINING SYSTEM LASER FUNCTION B-64663EN/01
- 128 -
Upper byte Lower byte Meaning
0 8
An end of record code (%) was sent during writing to a specified block.
Make sure so that "%" is not sent.
0 9
The number of registered records exceeds 125 (basic), or 200, 400, or
1000 (option).
1 0
An attempt was made to register a program with a number with which
another was already registered.
1 1 A specified program number does not fall within the range of 1 to 9999.
1 2
An attempt was made to edit programs No. 8000 to 8999, or programs
No. 9000 to 9999. This alarm occurs if the specification of a parameter
inhibits the editing of such programs. See the description of NC
parameter No. 3202 for details.
1 3 The number of specified blocks exceeds 9999.
1 4
An attempt was made to write more than 99 characters to a specified
block.
1 5 The delete command is incorrect.
1 6 The macro program is incorrect.
1 7
An attempt was made to read more than 120 characters from a specified
block.
1 8
A program cannot be edited by teaching, because background editing
occurs in the NC.
1 9
A specified program number, sequence number, or block length has a
negative value.
2 0
An end of record code (%) was detected during reading from a specified
block. This means that the last block was read.
3 0
In a sequence number search, a non-numeric item was specified for a
program or block number.
3 1
During teaching box MDI operation, a numeric value was specified with
no address specified.
3 2 During teaching box MDI operation, command O or N was issued.
3 3
During teaching box MDI operation, a specified numeric value consists
of more than eight digits (excluding a minus sign).
3 4 During teaching box MDI operation, an invalid address was specified.
3 5
During teaching box MDI operation, an MDI operation was requested
during the execution of another program.
3 6
In area R of the PMC, an error occurred during the setting of the DI/DO
extended area.
5 0
For the step forward or step reverse function, a macro statement was
specified.
5 1
For the step forward or step reverse function, an invalid G code was
specified.
5 3
The next command was rejected because it was issued during execution
of the step forward or step reverse function.
5 5 No option was specified for the step forward or step reverse function.