5.LASER OUTPUT CONTROL LASER FUNCTION B-64663EN/01
- 80 -
5.5 GUIDE LIGHT ON SIGNAL
Overview
If the laser oscillator contains an optional guide light unit
(semiconductor laser), an external signal can be used to turn the guide
light laser unit on or off.
CAUTION
The external guide light on signal (SCLON) must
be used with a key-operated switch, the key of
which cannot be removed while the guide light is
turned on.
Signal
- Guide light on signal
SCLON<G222#2>
[Classification] Input signal
[Function] Turns on the laser unit for the laser oscillator guide light.
[Operation] (1) C-series oscillator
If the laser oscillator contains an optional guide light unit
(semiconductor laser), setting the guide light on signal (SCLON)
to 1 turns on the guide light laser unit.
In this state, the oscillator outputs the guide light when the
shutter is closed. When the shutter is open, the oscillator outputs
carbon dioxide gas laser instead of the guide light.
The external guide light on signal (SCLON) must be used with a
key-operated switch
, the key of which cannot be removed while
the guide light is turned on.
(2) Y-series oscillator
Each YAG laser oscillator contains a guide light unit
(semiconductor laser). When the guide light on signal (SCLON)
is set to 1, the guide light laser unit is turned on.
When the shutter is opened in this condition, the oscillator
outputs the guide light, either together with or without the YAG
laser. When the shutter is closed, the oscillator outputs neither
the guide light nor the YAG laser.
The external guide light on signal (SCLON) must be used with a
key-operated switch
, the key of which cannot be removed while
the guide light is turned on.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G222 SCLON