5.LASER OUTPUT CONTROL LASER FUNCTION B-64663EN/01
- 72 -
- Mode output signal
CW<F222#6>
[Classification] Output signal
[Function] Notifies the PMC that the beam is output in continuous (CW) mode. In
continuous mode, the pulse duty ratio of the output command, multiplied
by the duty override, is 100%. Power control is not performed.
[Output condition] The signal is set to 1 when:
- The beam is output in continuous (CW) mode.
The signal is set to 0 when:
- The beam is not output.
- The beam is output in pulse mode.
- Mode output signal
PULSE<F222#5>
[Classification] Output signal
[Function] Notifies the PMC that the beam is output in pulse mode. In pulse
mode, the pulse duty ratio of the output command, multiplied by the
duty override, is less than 100%. Or, power control is used to select
the pulse output state.
[Output condition] The signal is set to 1 when:
- The beam is output in pulse mode.
The signal is set to 0 when:
- The beam is not output.
- The beam is output in continuous (CW) mode.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G222 BEMON SHTON *BEMLC *SHTLC
F220 SHTONL SHTOFL
F221 BEAM
F222 CW PULSE
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
15001 LHC
[Data type] Bit
LHC Oscillator control (shutter open/close, beam on/off, assist gas control)
is:
0: Not performed by external signals. The beam is turned on and off
by a G code. (standard setting)
1: Performed by external signals. The beam is turned on and off by
the beam on signal (BEMON).
Alarm and message
No. Message Contents
4068
BEAM
REFLECTION
Beam reflection from the workpiece is greater
than or equal to the specified standard level.