8.CONTROL FUNCTION LASER FUNCTION B-64663EN/01
- 192 -
2 The cutting operation is performed with the cutting output peak
value specified, the return speed being used as the feedrate, and
the return frequency and duty cycle being as those of the output
power. These conditions continue until the return distance is
moved through.
3 After the return distance is moved through, the machining
conditions of the cutting command are selected, and machining
continues under these conditions.
Setting the data
The edge machining data for the machining condition setting function
is used for start-up machining. The data area for the edge machining
condition setting function can hold five sets of the data items listed
below. The data items that have no value in this table are ignored in
the start-up function.
Item Setting range Setting unit
Edge operation angle
Piercing peak value
Piercing pulse frequency
Piercing pulse duty cycle
Piercing time
Piercing assist gas pressure
Piercing assist gas type
Return distance
Return speed
Return frequency
Return duty cycle
-
-
-
-
-
-
-
1 to 99.999
1 to 9999
5 to 2000
0 to 100
-
-
-
-
-
-
-
mm
mm/min
Hz
%
The return distance cannot exceed the length of a single block.
Return peak value Sb' can be specified in parameter No. 15059. This
is intended to use the output peak value Sb' that is different from the
peak value Sb of block B during movement through the distance Lr. If
this parameter is 0, machining is performed with Sb' = Sb.
Selecting the start-up function
The stat-up function is enabled by setting an edge data number from
201 to 205 in the "start-up selection" item in the machining data group.
To disable this function, reset the "start-up selection" item to 0.
Start-up command
If a program specifies a machining data set number using the E
address, when the program is executed, the "start-up selection" item in
the specified machining data is referenced, and the edge data set
number is read for execution of the start-up function.
Override
Override is applied to the following item.
1 Return speed
2 Return peak value
3 Return frequency
4 Return duty cycle