OPERATION
B–63084EN/02
12. GRAPHICS FUNCTION
671
WORK LENGTH (W), WORK DIAMETER (D)
Specify work length and work diameter. The table below lists the input
unit and valid data range.
W
D
X
Z
W
D
Z
X
Table 12.1 Unit and Range of Drawing Data
Unit
Increment system
mm input Inch input
Valid range
IS–B 0.001 mm 0.0001 inch
IS–C 0.0001 mm 0,00001 inch
0 to 99999999
GRAPHIC CENTER (X, Z), SCALE (S)
A screen center coordinate and drawing scale are displayed. A scale
screen center coordinate are automatically calculated so that a figure
set in WORK LENGTH (a) and WORK DIAMETER (b) can be fully
displayed on the screen. So, the user need not set these parameters
usually.
A screen center coordinate is defined in the workpiece coordinate
system. Table 12. 3. 2 indicates the unit and range. The unit of SCALE
is 0.001%.
PROGRAM STOP (N)
Set the sequence number of an end block when part of the program is
to be drawn. A value set in this parameter is automatically cancelled
(cleared to 0) once a drawing is provided.
AUTO ERASE (A)
If 1 is set, the previous drawing is automatically erased when
automatic operation is stated from the reset state. Then, drawing is
started.
LIMIT (L)
If 1 is set, the area of stored stroke limit l is drawn with
double–dot–and–dash lines.
NOTE
The parameter values for drawing are preserved even if
power is turned off.
Since the graphic drawing is done when coordinate value is renewed
during automatic operation, etc., it is necessary to start the program by
automatic operation. To execute drawing without moving the machine,
therefore, enter the machine lock state.
D Graphics parameter
D Executing drawing only